Description
INSPECTION AND ADJUSTMENT
ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Description
When the control unit is replaced, initialization is necessary.
If any of the following operations are performed, initialization is necessary as well as when the control unit is disconnected.
- Power supply to the power window control unit is cut off by the removal of battery terminal or the battery fuse is blown.
- Disconnection and connection of power window control unit harness connector.
- Removal and installation of motor from regulator assembly.
- Disconnection and connection of battery negative terminal.
- Removal and installation of rear power window control unit.
- Removal and installation of door glass.
- Removal and installation of door glass run.
The following specified operations cannot be performed while initialization is not complete.
- AUTO-UP operation
- Anti-pinch function
- Door key cylinder power window function