Operation CHARM: Car repair manuals for everyone.

Special Repair Requirement





INSPECTION AND ADJUSTMENT


ADDITIONAL SERVICE WHEN REPLACING CONTROL UNIT : Special Repair Requirement


INITIALIZATION PROCEDURE
1. Disconnect battery negative terminal or power window control unit connector. Reconnect it after a minute or more.
2. Turn ignition switch ON.
3. Operate power window switch to fully open door glass. (This operation is unnecessary if door glass is already fully open.)
4. Pull and hold power window switch UP (AUTO-UP operation). Even after door glass stops at the fully closed position, pull the switch for 2 seconds or more.
5. Initialization procedure is complete.
6. Inspect anti-pinch function.

CHECK ANTI-PINCH FUNCTION
1. Fully open door glass.
2. Place a piece of wood near the fully closed position.
3. Close door glass completely using AUTO-UP.
- Check that door glass lowers approximately 150 mm (5.9 in) without pinching piece of wood and stops.
- Check that door glass does not rise when operating power window main switch while lowering.

CAUTION:
- Perform initialization when AUTO-UP operation or anti-pinch function does not operate normally.
- Check that AUTO-UP operates before inspection when initialization is performed.
- Never check with hands or other body parts because they may be pinched. Never get pinched.
- It may switch to the fail-safe mode if open/close operation is performed continuously without fully closing. Perform initialization in the above situation. Power Window Main Switch.
- Finish initialization. Otherwise, the next operation cannot be done.
1. AUTO-UP operation
2. Anti-pinch function
3. Door key cylinder power window function