Automatic Air Conditioner Compressor Control Function
COMPRESSOR CONTROL FUNCTION
Fail-Safe
FAIL-SAFE FUNCTION
- If a communication error exists between the unified meter and A/C amp., and preset switch for 30 seconds or longer, air conditioner is controlled under the following conditions:
Compressor : ON
Air outlet : AUTO
Air inlet : FRE (Fresh)
Blower fan speed : AUTO
Set temperature : Setting before communication error occurs
Display : OFF