INSPECTION AND ADJUSTMENT


ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Description

When battery negative terminal is disconnected, initialization is necessary.
If any of the following operations are performed, initialization is necessary as well as when battery negative terminal is disconnected.
- Power supply to the power window control unit is cut off by the removal f battery terminal or the battery fuse is blown.
- Disconnection and connection of power window control unit harness connector.
- Removal and installation of motor from regulator assembly.
- Operation of regulator assembly as an independent unit.
- Removal and installation of rear power window control unit.
- Removal and installation of door glass.
- Removal and installation of door glass run.
The operations as per the following cannot be performed while initialization is not complete.
- AUTO-UP operation
- Anti-pinch function
- Door key cylinder power window function