Operation CHARM: Car repair manuals for everyone.

Work Procedure





VVEL CONTROL SHAFT POSITION SENSOR ADJUSTMENT


Work Procedure

1.START
Will CONSULT-III be used?
Will CONSULT-III be used?
YES - GO TO 2.
NO - GO TO 3.
2.PERFORM VVEL CONTROL SHAFT POSITION SENSOR ADJUSTMENT
WITH CONSULT-III
1. Turn ignition switch ON.
2. Select "VVEL POS SEN ADJ PREP" in "WORK SUPPORT" mode with CONSULT-III.
3. Touch "Start" and wait a few seconds.
4. Check that "CMPLT" is displayed on CONSULT-III screen.
5. Select "VVEL POSITION SEN-B1" or "VVEL POSITION SEN-B2" in "DATA MONITOR" mode with CONSULT-III.





6. Loosen the VVEL control shaft position sensor mounting bolts
(1).
7. Turn the VVEL control shaft position sensor (2) clockwise and counterclockwise while monitoring the output voltage of "VVEL
POSITION SEN-B1" or "VVEL POSITION SEN-B2" and adjust the output voltage to be within the standard value.

Voltage: 500 ± 48 mV

8. Tighten the VVEL control shaft position sensor mounting bolts.


Tightening torque: 7.0 N-m (0.71 kg-m, 62 in-lb)

9. Reconfirm that the output voltage of "VVEL POSITION SEN-B1" or "VVEL POSITION SEN-B2" is within the standard value.

Voltage: 500 ± 48 mV

NOTE:
If it varies from the standard value after the mounting bolts are tightened, perform steps 6 to 8 again.
10. Turn ignition switch OFF and wait at least 10 seconds.
11. Start engine and warm it up to normal operating temperature.
12. Turn ignition switch OFF and wait at least 10 seconds.
13. Perform idle air volume learning. Work Procedure.
- INSPECTION END
3.PERFORM VVEL CONTROL SHAFT POSITION SENSOR ADJUSTMENT
WITHOUT CONSULT-III
1. Disconnect VVEL control shaft position sensor harness connector.
2. Remove VVEL actuator motor relay.
3. Turn ignition switch ON, wait at least 5 seconds and then turn it OFF.
4. Reconnect all harness connectors disconnected.
5. Install VVEL actuator motor relay.
6. Turn ignition switch ON and wait at least 5 seconds.





7. Loosen the VVEL control shaft position sensor mounting bolts
(1).
8. Turn the VVEL control shaft position sensor (2) clockwise and counterclockwise while monitoring the output voltage between the VVEL control module terminals with a tester and adjust the output voltage to be within the standard value.





9. Tighten the VVEL control shaft position sensor mounting bolts.

Tightening torque: 7.0 N-m (0.71 kg-m, 62 in-lb)

10. Reconfirm that the output voltage of VVEL control shaft position sensor is within the standard value.






NOTE:
If it varies from the standard value after the mounting bolts are tightened, perform steps 7 to 9 again.
11. Turn ignition switch OFF and wait at least 10 seconds.
12. Start engine and warm it up to normal operating temperature.
13. Turn ignition switch OFF and wait at least 10 seconds.
14. Perform Idle Air Volume Learning. Work Procedure.
- INSPECTION END