Heating and Air Conditioning: Adjustments
INSPECTION AND ADJUSTMENT
Exhaust Gas/Outside Odor Detecting Sensor Sensitivity Adjustment Function (With ACCS)
DESCRIPTION
According to customer's sense of smell, exhaust gas / outside odor detecting sensor sensitivity can be changed.
1.Begin self-diagnosis STEP-5 mode. Diagnosis Description.
2.Press fan (UP: +) switch two times to set system in auxiliary mode.
3.Turn temperature control dial (driver side) as desired.
NOTE:
When battery cable is disconnected or battery voltage is below 10 V, exhaust gas/outside odor detecting sensor sensitivity adjustment function is canceled. Exhaust gas / outside odor detecting sensor sensitivity adjustment function set becomes that of initial condition.