Keyless Entry Transmitter: Testing and Inspection
INTELLIGENT KEY LOW BATTERY WARNING DOES NOT OPERATE
Description
NOTE:
- Before performing the diagnosis in the following procedure, check "Work Flow". Work Flow.
- Warning functions operating condition is extremely complicated, during operating confirmations, reconfirm the list above twice in order to ensure proper operation. Warning Function.
Diagnosis Procedure
1. CHECK "LO- BATT OF KEY FOB WARN" SETTING IN "WORK SUPPORT"
Check "LO- BATT OF KEY FOB WARN" setting in "WORK SUPPORT".
Intelligent Key.
Is the inspection result normal?
YES- GO TO 2.
NO- Set "LO- BATT OF KEY FOB WARN" setting in "WORK SUPPORT".
2. CHECK INTELLIGENT KEY BATTERY
Check Intelligent Key battery.
Intelligent Key.
Is the inspection result normal?
YES- GO TO 3.
NO- Repair or replace the malfunctioning parts.
3. CHECK COMBINATION METER DISPLAY
Check combination meter display.
Combination Meter Display Function.
Is the inspection result normal?
YES- GO TO 4.
NO- Repair or replace the malfunctioning parts.
4. CHECK INSIDE KEY ANTENNA
Check inside key antenna.
B2621 (instrument center).
B2623 (luggage room).
Is the inspection result normal?
YES- GO TO 5.
NO- Repair or replace the malfunctioning parts.
5. CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES- Check intermittent incident. Intermittent Incident.
NO- GO TO 1.