Operation CHARM: Car repair manuals for everyone.

Combination Meter




POWER SUPPLY AND GROUND CIRCUIT

COMBINATION METER : Diagnosis Procedure


1. CHECK FUSE

Check for blown fuses.





Is the inspection result normal?
YES- GO TO 2.
NO- Be sure to eliminate cause of malfunction before installing new fuse.

2. CHECK POWER SUPPLY CIRCUIT

Check voltage between combination meter harness connector and ground.





Is the inspection result normal?
YES- GO TO 3.
NO- Check harness between combination meter and fuse.

3. CHECK GROUND CIRCUIT

1.Turn ignition switch OFF.
2.Disconnect combination meter connector.
3.Check continuity between combination meter harness connector and ground.





Is the inspection result normal?
YES- INSPECTION END
NO- Repair harness or connector.