Initial Inspection and Diagnostic Overview
POWER SUPPLY AND GROUND CIRCUIT
BCM : Diagnosis Procedure
1. CHECK FUSE AND FUSIBLE LINK
Check that the following fuse and fusible link are not blown.
Is the fuse fusing?
YES- Replace the blown fuse or fusible link after repairing the affected circuit if a fuse or fusible link is blown.
NO- GO TO 2.
2. CHECK POWER SUPPLY CIRCUIT
1.Turn ignition switch OFF.
2.Disconnect BCM connectors.
3.Check voltage between BCM harness connector and ground.
Is the measurement value normal?
YES- GO TO 3.
NO- Repair harness or connector.
3. CHECK GROUND CIRCUIT
Check continuity between BCM harness connector and ground.
Does continuity exist?
YES- INSPECTION END
NO- Repair harness or connector.