Diagnosis Procedure
AUTOMATIC BACK DOOR OPERATION DOES NOT OPERATE
CLOSURE FUNCTION : Diagnosis Procedure
1. CHECK HALF LATCH SWITCH
Check half latch switch.
Half Latch Switch.
Is the inspection result normal?
YES- GO TO 2.
NO- Repair or replace the malfunctioning parts.
2. CHECK BACK DOOR CLOSURE MOTOR
Check back door closure motor.
Back Door Closure Motor.
Is the inspection result normal?
YES- GO TO 3.
NO- Repair or replace the malfunctioning parts.
3. REPLACE AUTOMATIC BACK DOOR CONTROL MODULE
1.Replace automatic back door control module. Automatic Back Door Control Module.
2.Confirm the operation after replacement.
Is the result normal?
YES- INSPECTION END
NO- Check intermittent incident. Intermittent Incident.