Power Windows Do Not Operate With Power Window Main Switch
POWER WINDOWS DO NOT OPERATE WITH POWER WINDOW MAIN SWITCH
Diagnosis Procedure
1. CHECK BCM POWER SUPPLY AND GROUND CIRCUIT
Check BCM power supply and ground circuit.
Service and Repair.
Is the inspection result normal?
YES- GO TO 2.
NO- Repair or replace the malfunctioning parts.
2. CHECK POWER WINDOW MAIN SWITCH POWER SUPPLY AND GROUND CIRCUIT
Check power window switch power supply and ground circuit.
Power Window Main Switch.
Is the inspection result normal?
YES- GO TO 3.
NO- Repair or replace the malfunctioning parts.
3. CHECK POWER WINDOW MAIN SWITCH SERIAL LINK CIRCUIT
Check power window serial link circuit.
Component Function Check.
Is the inspection result normal?
YES- GO TO 4.
NO- Repair or replace the malfunctioning parts.
4. CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES- Check intermittent incident. Intermittent Incident.
NO- GO TO 1.