Power Window Down Function Does Not Work When Operating With Intelligent Key
POWER WINDOW DOWN FUNCTION DOES NOT WORK WHEN OPERATING WITH INTELLIGENT KEY
Description
NOTE:
- Before performing the diagnosis in the following procedure, check " Work Flow". Refer to "Work Flow" Work Flow.
Diagnosis Procedure
1. CHECK REMOTE KEYLESS ENTRY FUNCTION
Check remote keyless entry function.
Does door lock/unlock with Intelligent key button?
YES- GO TO 2.
NO- Go to "Description" Door Does Not Lock/Unlock With Intelligent Key.
2. CHECK POWER WINDOW OPERATION
Check power window operation.
Does power window up/down with power window main switch?
YES- GO TO 3.
NO- Go to "Diagnosis Procedure" Power Windows Do Not Operate With Any Power Window Switches.
3. CHECK "PW DOWN SET" SETTING IN "WORK SUPPORT"
Check "PW DOWN SET" setting in "WORK SUPPORT".
Refer to "INTELLIGENT KEY : CONSULT Function (BCM INTELLIGENT KEY)" Intelligent Key.
Is the inspection result normal?
YES- GO TO 4.
NO- Set "PW DOWN SET" setting in "WORK SUPPORT".
4. CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES- Check intermittent incident. Refer to "Intermittent Incident" Intermittent Incident.
NO- GO TO 1.