Operation CHARM: Car repair manuals for everyone.

Temperature Setting Trimmer




INSPECTION AND ADJUSTMENT

Temperature Setting Trimmer


DESCRIPTION

The trimmer compensates for differences in range of �3�C (�6�F) between temperature setting (displayed digitally) and temperature felt by customer.
1.Begin self-diagnosis STEP-5 mode. Refer to "Diagnosis Description" Diagnosis Description.
2.Press fan (UP: +) switch to set system in auxiliary mode.
3.Display shows "61" in auxiliary mechanism. It takes approximately 3 seconds to enable setting operation.
4.Turn temperature control dial (driver side) as desired. Temperature will change at a rate of 0.5�C (1.0�F)
each time a dial is turned.

CAUTION:
A decimal point is not indicated on the display.





When battery cable is disconnected or battery voltage is below 10 V, trimmer operation is canceled. Temperature set becomes that of initial condition, i.e. 0�
C (0�F).