Trip A/B Reset Switch Signal Circuit
TRIP A/B RESET SWITCH SIGNAL CIRCUIT
Description
Transmits the trip A/B reset switch signals to the combination meter.
Diagnosis Procedure
1. CHECK TRIP A/B RESET SWITCH INPUT SIGNAL
1.Turn ignition switch ON.
2.Measure voltage between the combination meter harness connector terminals.
Is the inspection result normal?
YES- INSPECTION END
NO- GO TO 2.
2. CHECK TRIP A/B RESET SWITCH SIGNAL CIRCUIT
1.Turn ignition switch OFF.
2.Disconnect the combination meter and meter control switch connectors.
3.Check continuity between combination meter harness connector and trip A/B reset switch harness connector.
4.Check continuity between combination meter harness connector and ground.
Is the inspection result normal?
YES- INSPECTION END
NO- Repair harness or connector.
Component Inspection
1. CHECK TRIP A/B RESET SWITCH UNIT
1.Turn ignition switch OFF.
2.Disconnect the trip A/B reset switch connector.
3.Check continuity between the trip A/B reset switch connector terminals.
Is inspection result normal?
YES- INSPECTION END
NO- Replace trip A/B reset switch.