Operation CHARM: Car repair manuals for everyone.

AC 120 V Outlet Main Switch Input Signal Circuit




AC 120 V OUTLET MAIN SWITCH INPUT SIGNAL CIRCUIT

Diagnosis Procedure

Regarding Wiring Diagram information, refer to "Wiring Diagram" Inverter Unit.

1. CHECK AC 120V OUTLET MAIN SWITCH INPUT SIGNAL

1.Turn ignition switch ON.
2.AC 120V outlet main switch ON.
3.Check for voltage between the inverter unit connector B82 terminal 6 and ground.





Is the inspection result normal?
YES- Inspection End.
NO- GO TO 2.

2. CHECK AC 120V OUTLET MAIN SWITCH

Check AC 120V outlet main switch. Refer to "Component Inspection (AC 120V Outlet Main Switch)" .
Is the inspection result normal?
YES- GO TO 3.
NO- Replace AC 120V outlet main switch.

3. CHECK HARNESS BETWEEN INVERTER UNIT AND AC 120V OUTLET MAIN SWITCH

1.Disconnect inverter unit connector.
2.Check for continuity between the inverter unit connector B82 terminal 6 and AC 120V outlet main switch connector M88 terminal 3.





3.Check for continuity between inverter unit connector B82 terminal 6 and ground.





Is the inspection result normal?
YES- Inspection End.
NO- Repair or replace the AC 120V outlet main switch input signal circuit.


Component Inspection (AC 120V Outlet Main Switch)


1. CHECK AC 120V OUTLET MAIN SWITCH

1.Turn ignition switch OFF.
2.Disconnect AC 120V outlet main switch connector.
3.Check continuity between terminals 1 and 3 of AC 120V outlet main switch.
Revision: March 20122013 Infiniti JX





Is the inspection result normal?
YES- Inspection End.
NO- Replace AC 120V outlet main switch.