No Output From AC 120 V Outlet
NO OUTPUT FROM AC 120 V OUTLET
Diagnosis Procedure
1. CHECK FAIL-SAFE ACTIVATION
Check if the symptom is caused by a fail-safe operation. Refer to "Fail-safe" Inverter Unit.
Is fail-safe operating?
YES- Repair the part causing fail-safe operation.
NO- GO TO 2.
2. CHECK INVERTER UNIT POWER SUPPLY CIRCUIT
Check inverter unit power supply circuit. Refer to "Diagnosis Procedure" Power Supply and Ground Circuit.
Is the inspection result normal?
YES- GO TO 3.
NO- Repair or replace the malfunctioning parts.
3. CHECK AC 120V OUTLET MAIN SWITCH POWER SUPPLY CIRCUIT
Check AC 120V outlet main switch power supply circuit. Refer to "Diagnosis Procedure" AC 120 V Outlet Main Switch Power Supply Circuit.
Is the inspection result normal?
YES- GO TO 4.
NO- Repair or replace the malfunctioning parts.
4. CHECK AC 120V OUTLET MAIN SWITCH INPUT SIGNAL CIRCUIT
Check AC 120V outlet main switch input signal circuit. Refer to "Diagnosis Procedure" AC 120 V Outlet Main Switch Input Signal Circuit.
Is the inspection result normal?
YES- GO TO 5.
NO- Repair or replace the malfunctioning parts.
5. CHECK INVERTER UNIT POWER OUTPUT CIRCUIT
Check inverter unit power output circuit. Refer to "Diagnosis Procedure" AC 120 V Power Output Circuit.
Is the inspection result normal?
YES- Refer to "Intermittent Incident" Intermittent Incident.
NO- Repair or replace the malfunctioning parts.
Revision: March 20122013 Infiniti JX