Operation CHARM: Car repair manuals for everyone.

Keyless Power Window Down Does Not Operate




KEYLESS POWER WINDOW DOWN DOES NOT OPERATE

Diagnosis Procedure


1. CHECK REMOTE KEYLESS ENTRY FUNCTION

Check remote keyless entry function.
Is the inspection result normal?
YES- GO TO 2.
NO- Refer to "Diagnosis Procedure" Door Does Not Lock/Unlock With Intelligent Key.

2. CHECK POWER WINDOW OPERATION

Check power window operation.
In the inspection result normal?
YES- GO TO 3.
NO- Refer to "POWER WINDOW MAIN SWITCH : Diagnosis Procedure" Power Window Main Switch.

3. CHECK "PW DOWN SET" SETTING IN "WORK SUPPORT"

Check "PW DOWN SET" setting in "WORK SUPPORT".
Is the inspection result normal?
YES- GO TO 4.
NO- Set "PW DOWN SET" setting in "WORK SUPPORT".

4. CONFIRM THE OPERATION

Confirm the operation again.
Is the inspection result normal?
YES- Check intermittent incident. Refer to "Intermittent Incident" Intermittent Incident.
NO- GO TO 1.
Revision: March 20122013 Infiniti JX