Retained Power Operation Does Not Operate Properly
RETAINED POWER OPERATION DOES NOT OPERATE PROPERLY
Diagnosis Procedure
1. CHECK DOOR SWITCH
Check door switch.
Refer to "Component Function Check" Door Switch.
Is the inspection result normal?
YES- GO TO 2.
NO- Repair or replace the malfunctioning parts.
2. CHECK POWER WINDOW MAIN SWITCH
Check power window main switch system.
Refer to "POWER WINDOW MAIN SWITCH : Diagnosis Procedure" Power Window Main Switch.
Is the inspection result normal?
YES- GO TO 3.
NO- Repair or replace the malfunctioning parts.
3. CHECK BCM POWER SUPPLY AND GROUND
Check BCM power supply and ground circuit.
Refer to "Diagnosis Procedure" Power Supply and Ground Circuit.
Is the inspection result normal?
YES- GO TO 4.
NO- Repair or replace the malfunctioning parts.
4. CHECK SUNROOF MOTOR ASSEMBLY POWER SUPPLY AND GROUND
Check sunroof motor assembly power supply and ground circuit.
Refer to "Diagnosis Procedure" Power Supply and Ground Circuit.
Is the inspection result normal?
YES- GO TO 5.
NO- Repair or replace the malfunctioning parts.
5. CHECK SUNROOF SWITCH
Check sunroof switch circuit.
Refer to "Component Function Check" Sunroof Switch.
Is the inspection result normal?
YES- GO TO 6.
NO- Repair or replace the malfunctioning parts.
6. CONFIRM THE OPERATION
Confirm the operation again.
Is the result normal?
YES- Check intermittent incident. Refer to "Intermittent Incident" Intermittent Incident.
NO- GO TO 1.