Automatic Back Door Functions Do Not Cancel
AUTOMATIC BACK DOOR FUNCTIONS DO NOT CANCEL
Diagnosis Procedure
1. CHECK THE OPERATION
Check automatic back door main switch function.
NOTE:
When the main switch is OFF, the automatic back door operation is not available by back door opener switch and automatic back door close switch.
Is the inspection result normal?
YES- Automatic back door system is normal.
NO- GO TO 2.
2. CHECK AUTOMATIC BACK DOOR MAIN SWITCH
Check automatic back door main switch.
Refer to "Component Function Check" Automatic Back Door Main Switch.
Is the inspection result normal?
YES- GO TO 3.
NO- Repair or replace the malfunctioning parts.
3. REPLACE AUTOMATIC BACK DOOR CONTROL MODULE
1.Replace automatic back door control module. Refer to "Removal and Installation" Automatic Back Door Control Module.
2.Confirm the operation after replacement.
Is the result normal?
YES- INSPECTION END
NO- Check intermittent incident. Refer to "Intermittent Incident" Intermittent Incident.