Power Supply and Ground Circuit
POWER SUPPLY AND GROUND CIRCUIT
Diagnosis Procedure
1. CHECK GROUND CIRCUIT
1.Turn ignition switch OFF.
2.Disconnect pre-crash seat belt control unit (driver side and passenger side) harness connector.
3.Check continuity between pre-crash seat belt control unit (driver side and passenger side) harness connector and ground.
Is the measurement value normal?
YES- GO TO 2.
NO- Repair or replace harness or connector.
2. CHECK POWER SUPPLY CIRCUIT-I
Check voltage between pre-crash seat belt control unit (driver side and passenger side) harness connector and ground.
Is the measurement value normal?
YES- INSPECTION END
NO- GO TO 3.
3. CHECK POWER SUPPLY CIRCUIT-II
1.Disconnect fuse block (J/B) harness connector.
2.Check continuity between pre-crash seat belt control unit (driver side and passenger side) harness connector and fuse block (J/B) harness connector.
3.Check continuity between pre-crash seat belt control unit (driver side and passenger side) harness connector and ground.
Is the measurement value normal?
YES- Check 10 A fuse (No. 6).
NO- Repair or replace harness or connector.