Charging System Preliminary Inspection
CHARGING SYSTEM PRELIMINARY INSPECTION
Inspection Procedure
1. CHECK BATTERY TERMINALS CONNECTION
Check if battery terminals are clean and tight.
Is the inspection result normal?
YES- GO TO 2.
NO- Repair battery terminals connection.
2. CHECK FUSE
Check for blown fuse and fusible link.
Is the inspection result normal?
YES- GO TO 3.
NO- Replace the blown fuse after repairing the applicable circuit.
3. CHECK "E" TERMINAL CONNECTION
Check if "E" terminal (alternator ground harness) is clean and tight.
Is the inspection result normal?
YES- GO TO 4.
NO- Repair "E" terminal connection.
4. CHECK DRIVE BELT TENSION
Check drive belt tension. Refer to "Checking" Procedures.
Is the inspection result normal?
YES- INSPECTION END
NO- Repair as needed.