Check Valve
Check Valve:
Remove check valve from the air manifold. Test for leakage by blowing air into the valve from the air pump side and from the air manifold side. A good valve will only pass air from the pump side. The valve is defective if air passes from the manifold side and should be replaced. A small amount of air leakage may be overlooked.