Main Relay (Computer/Fuel System): Testing and Inspection
Check continuity between the Relay Terminals.
1 - 2 .... No Continuity.
3 - 4 .... No Continuity.
When battery voltage is applied between 5 and 6.
1 - 2 .... Continuity.
3 - 4 .... Continuity.