Maintenance: Service and Repair
OXYGEN SENSOR LIFE INDICATOR LIGHT (O2) RESET PROCEDUREAt 90,000 mile intervals, the O2 sensor lamp will illuminate.
After replacing the sensor, perform the following procedure to reset the lamp.
Maintainence Reminder Light Reset:
- Remove instrument cluster.
- Remove masking tape from hole B.
- Remove screw from hole A and install into hole B.
- Apply new masking tape to hole A.
- Install instrument cluster.
NOTE: This procedure assumes that the sensor is being replaced for the first time (at 90,000 miles). For subsequent procedures (every 90,000 miles) the procedure will be reversed.