Operation CHARM: Car repair manuals for everyone.

Component Tests and General Diagnostics

With the Ignition Switch in RUN or START, voltage is supplied from the TURN B/U Fuse to the Backup Lamp Switch. Whenever the gear selector lever is shifted to REVERSE, the Backup Lamp Switch closes and voltage is supplied to the Backup Lamps. The Backup Lamps remain ON as long as the Backup Lamp Switch is closed.