Blower Link Unit and / or Mode Door
Blower Link Unit and / or Mode DoorDisassembled View:
Removal
1. Disconnect the battery ground cable.
2. Discharge and recover refrigerant (with air conditioning).
3. Remove blower assembly.
4. Remove lower case.
5. Separate the upper case and slit the lining parting face with a knife.
6. Pull out the mode door while raising up the catch of door lever.
7. Remove sub-lever.
8. Remove door lever.
Installation
To install, follow the removal steps in the reverse order, noting the following points:
1. Apply grease to the door lever and to the abrasive surface of the upper case.
2. Apply an adhesive to the parting face of the lining when assembling the upper case.