Blower Motor Relay: Testing and Inspection
Relays - Test:
There should be continuity between the A and C terminals when power and ground are connected to the B and D terminals, and there should be no continuity when power is disconnected.
Radiator Fan Relay:
- Blower motor relay
Normally-open type A:
1. Check for continuity between the terminals.
- There should be continuity between the No. 1 and No. 3 terminals when power and ground are connected to the No. 2 and No. 4 terminals.
- There should be no continuity between the No. 1 and No. 3 terminals when power is disconnected.
Radiator Fan Relay/Power Window Relay/Blower Motor Relay:
- Blower motor relay