Blower Motor: Testing and Inspection
1. Disconnect the blower motor (B-5) connector from the blower motor.
2. Connect the battery positive terminal to the No. 1 terminal of the blower motor and negative to the No. 2.
3. Be sure to check to see if the blower motor operates correctly.