1. Getting Started
Before operating the Isuzu PCMCIA card with the Tech 2, the following steps must be performed:- The Isuzu 98 System PCMCIA card (1) inserts into the Tech 2 (5).
- Connect the SAE 16/19 adapter (3) to the DLC cable (4).
- Connect the DLC cable to the Tech 2 (5)
- Make sure the vehicle ignition is off.
- Connect the Tech 2 SAE 16/19 adapter to the vehicle ALDL/DLC.
- Turn on the vehicle ignition.
- Power the Tech 2 ON and verify the Tech 2 power up display.
NOTE: The RS232 Loop back connector is only to use for diagnosis of Tech 2. Refer to user guide of the Tech 2.
Part 1 Of 2:
Part 2 Of 2:
Operating Procedure (For Example)
The power up screen is displayed when you power up the tester with the Isuzu systems PCMCIA card. Follow the operating procedure.
Menu
- The table shows which functions are used for the available equipment versions