Evaporative Emission Control Canister: Service and Repair
REMOVAL1. Disconnect the negative battery cable.
2. Disconnect the three hoses from the EVAP canister.
3. Disconnect the fuel vapor connector and the purge hose from the EVAP canister vent solenoid.
4. Remove the retaining two bolts on the mounting bracket and slide the canister out of mounting bracket.
INSTALLATION
1. Slide the canister into mounting bracket and install the mounting bracket two bolts.
2. Connect the fuel vapor connector to the EVAP canister vent solenoid.
3. Connect the three hoses to the EVAP canister.
4. Disconnect the negative battery cable.