Circuit Operation
Battery voltage is applied at all times from the positive battery terminal to the
starter switch and the normally open
starter solenoid contacts. When the starter switch is turned to START and the Antitheft system is deactivated, and with the automatic transmission mode switch closed, battery voltage is applied to the
starter relay coil. The starter relay energizes and applies battery voltage to the starter solenoid coils. The starter solenoid coils energize, the starter solenoid contact closes, and battery voltage is applied to the
starter motor. The starter motor engages to start the engine.