Manifold Pressure/Vacuum Sensor: Service and Repair
Removal Procedure1. Remove the electrical connector.
2. Remove the attaching screw (1).
3. Remove the bracket (2).
4. Remove the MAP sensor (3) from the intake manifold (4).
Installation Procedure
1. Install the MAP sensor (3) into the intake manifold (4).
2. Install the MAP sensor bracket (2).
NOTE: Refer to Fastener Note in Service Precautions.
3. Install the attaching screw (1).
Tighten
Tighten the attaching screws to 5 N.m (44 lb in).
4. Install the electrical connector.