Operation CHARM
: Car repair manuals for everyone.
Home
>>
Isuzu Truck
>>
2000
>>
Rodeo LS 2WD V6-3.2L
>>
Repair and Diagnosis
>>
Sensors and Switches
>>
Sensors and Switches - HVAC
>>
Refrigerant Pressure Sensor / Switch
>>
Description and Operation
>>
Cycling Switch
Cycling Switch
MEDIUM PRESSURE SWITCH
Low and high switch operation is the same as the dual pressure switch. The medium pressure switch will close when system pressure exceeds
1471.5 ± 98.1 kPa (213.3 ± 14.2 psi)
, turning on the condenser fan.