Pickup Coil
- Disconnect electrical connector.
Pickup Coil:
- Using an ohm meter, check the resistance between each pickup coil terminal and distributor housing.
RESISTANCE VALUE
Infinite (open)
Pickup Coil:
- Using an ohm meter, check the resistance between each pickup coil terminal.
RESISTANCE VALUE
500 - 1500 (0.5k - 1.5k) ohms
- Replace pickup coil if faulty.