Test 19 - Warning Lamp Output Short Circuit
Test LB14- (-) for short circuit to ground.If not ground, fault in instrument pack.
If ground, disconnect LB14 (-) C.P.U.
Test LB 14-3 (-) male for short circuit to ground.
If not ground, fault is short circuit in C.P.U.
If ground, disconnect LB107 (-) and repeat short circuit test.
If not ground, fault is short circuit in warning lamp assembly.
If ground, disconnect LB54 (-) and repeat short circuit test.
If not ground, fault is short circuit in instrument pack.
If ground, fault is short circuit in bulkhead harness.