Test 10 - Door Input Open Circuit
Test LB86-4 (LB86-15) for short circuit to ground.If ground, test passed.
If not ground, test LB118-86 (-) for short circuit to ground.
If ground, fault is open circuit bulkhead harness.
If not ground, test LB118-87A (-) for short circuit to ground.
If ground, either relay or reverse lamp circuit at fault.
If not ground, test LB61-32 (LB8-20) for short circuit to ground.
If ground, fault is open circuit in the bulkhead harness.
TEST 10 - DOOR INPUT OPEN CIRCUIT
If not ground, test DD9-5 (PD2-5) for short circuit to ground.
If ground, fault is open circuit in door harness.
If not ground, test DD9-6 (PD2-6) for short circuit to ground.
If ground, fault is open-circuit door switch.
If not ground, test LB62-6 (LB7-6) for short circuit to ground.
If ground, fault is open circuit in door harness.
If not ground, fault is open circuit in the bulkhead harness.