Test 11 - Door Input Short Circuit
Test LB86-4 (LB86-15) for short circuit to ground.If not ground, test passed.
If ground, disconnect passive restraint module.
Test LB86-4 (LB86-15) male for short circuit to ground.
If not ground, fault is a short circuit in the passive restraint module.
If ground, disconnect DD9 (PD2) and repeat short circuit test.
If not ground, fault is short circuit door switch.
If ground, disconnect DD2 (PD8) and repeat short circuit test.
If not ground, fault is short circuit in door switch pack assembly.
If ground, disconnect LB61 (LB8) and repeat short circuit test.
If not ground, fault is short circuit in door harness.
TEST 11 - DOOR INPUT SHORT CIRCUIT
If ground, disconnect LB118 (-).
Test LB118-87A (-) for short circuit to ground.
If ground, fault is short circuit in bulkhead harness.
If not ground, check LB86-4 (LB86-15) for short circuit to ground.
If not ground, fault is short circuit in reverse inhibit relay.
If ground, fault is short circuit in bulkhead harness.