Idle Up Control Valve: Testing and Inspection
Idle Air Components:
1. Disconnect supplementary air valve harness connector from main harness. Do not apply voltage to main harness.
2. Ground yellow/green wire in air valve connector.
3. Apply 12 volts to white/brown wire in air valve connector.
4. Valve is normally closed and should open when voltage is applied.