Air Flow Meter/Sensor: Service and Repair
REMOVE
- Open the hood and disconnect the battery earth lead.
- Remove the nuts securing the air cleaner to the inner wing valance.
- Release the clips securing the air cleaner to the air mass meter and reposition the air cleaner for access.
- Release the air mass meter to intake elbow hose clip.
- Remove the screw securing the air mass meter earth lead and disconnect the earth lead.
- Disconnect the air mass meter connector (black and remove the air mass meter.
REFIT
- Connect the air mass meter connector (black to the new air mass meter.
- Connect the air mass meter earth lead.
- Fit the air mass meter to to intake elbow hose and tighten the hose clip.
- Fit the air cleaner to the air mass meter and engage the securing clips.
- Secure the air cleaner to the inner wing valance and tighten the securing nuts.
- Connect the battery earth lead and close the hood.