Muffler to Condenser
Muffler To CondenserRemoval
1. Depressurize the air conditioning system.
2. Loosen the union nut from the condenser stub pipe and remove the hose. Tighten to 28-37 Nm (20.6-27.8 ft lb).
3. Remove and discard the "0" ring seal.
4. Fit a protective cap to the condenser outlet.
5. Loosen the union nut connecting the hose to the muffler and disconnect the hose. Tighten to 28-37 Nm (20.6-27.8 ft lb).
6. Remove and discard the "0" ring seal.
7. Fit a protective cap to the muffler outlet pipe and remove the hose.
Installation
NOTE:
- Installation is the reverse of the removal procedure.
- Ensure that new "O" rings are fitted and the protective
caps are not removed until the last possible moment
before connecting the new hose.
- Ensure the union nuts are tightened to the correct torque.
- Flush the system, fit a new dryer bottle. Evacuate and recharge the system.