Operation CHARM: Car repair manuals for everyone.

Instrument Panel Module, Renew

INSTRUMENT PANEL MODULE

Fig 1:





RENEW

Disconnect the battery earth cable. Position the tilt steering column to the lowest position.

Remove the instrument panel finishers' securing screws and remove the central and side finishers (1 Fig. 1).

Remove the instrument panel to fascia securing screw cover plates and remove the screws securing the instrument panel to the fascia (2 Fig. 1). Ease the instrument panel foward for access and disconnect the multiplugs.

Remove the instrument panel.

Note: To minimize the risk of damage and contamination, all repairs conducted on the Instrument Pack should be performed in a non-static dust free environment.

Position the new instrument panel adjacent to the mounting position and connect the multiplugs. Fully seat the instrument panel.

Fit and tighten the instrument panel to the fascia and secure the screws.

Fit the securing screw finishers.

Position and fit the side and central finishers and secure the screws.

Reposition the steering column to the original position.

Reconnect the battery earth cable.