Removal Procedure:
FIG. 1:
Position the plate section of tool JD 119 in a vise, (fig. 1).
FIG. 2:
^ Hold (by its wire) one of the two nuts under a cut-out of the pump's drive dog flange, (fig. 2).
FIG. 3:
FIG. 4:
^ Screw one of the two bolts into the nut and tighten it, (fig. 3). Repeat this procedure for the other nut and bolt, but only enter the bolt by approximately two threads. Position the pump under the plate, (fig. 4).
FIG. 5:
^ Position the bolt heads in the slots to support the pump and tighten the second bolt (fig. 5).
FIG. 6:
^ Assemble tool 18G 1445 as indicated in fig. 6. Ensure that the hexagon (1) is below the plate and the two flats (2) above the plate. Screw the center bolt of the tool into the pump shaft so that it is fully engaged and finger tight. Screw the center section's hexagon up so that it contacts the underside of the plate.
FIG. 7:
^ Using a 22 mm wrench, hold the center bolt so that it cannot turn, (fig. 3). Using a 19 mm open ended wrench, turn the center section of the tool counter-clockwise to remove the drive dog.
FIG. 8:
^ Hold the pump and loosen the center bolt to release the pump, (fig. 8). Lift out tbe drive dog.