Operation CHARM: Car repair manuals for everyone.

Service Specifications

Distributor Ident. No.
Note: Stamped on distributor housing. If unit is checked on vehicle, double the RPM & degrees to get crankshaft figures.
3242700
Centrifugal Advance Starts - 1/2 to + 1/2 at 500 Degrees At RPM (deg @ rpm)
Intermediate Advance A 0-3 at 600 Degrees At RPM (deg @ rpm)
B 2 1/2 -4 1/2 at 1200 Degrees At RPM (deg @ rpm)
C 6-8 at 1600 Degrees At RPM (deg @ rpm)
Full Advance 12 at 2400 Degrees At RPM (deg @ rpm)
Vacuum To Start Plunger 2-5 Inch Of Mercury (in Hg)
Max. Advance 11 1/2 at 17 Degrees At RPM (deg @ rpm)