Oxygen Sensor: Testing and Inspection
Disconnect the
oxygen sensor electrical connector from the wiring harness, and connect an ohmmeter across terminals A and B of the sensors electrical connector. Resistance value should be between 5 and 7 ohms. Replace the sensor if the resistance reading is not within the previous specifications or if the ohmmeter indicates infinite resistance.