Output Shaft
Fig. 125:
Check thickness of the output shaft flange with a micrometer or vernier calipers. Minimum allowable flange thickness is 4.70 mm (0.185 inch).
Check diameter of the first, second, and third gear bearing surfaces on the output shaft. Minimum diameters are as follows:
- First gear bearing surface is 38.86 mm (1.529 inch).
- Second gear bearing surface is 46.86 mm. (1.844).
- Third gear bearing surface is 37.86 mm (1.490 inch).
Measure output shaft runout with a dial indicator and V-blocks. Runout should not, exceed 0.06 mm (0.0024 inch).
Replace output shaft if measurement of any surface is out of specification. Do not attempt to repair out of specification components.