Loss of Ignition Run/Start (Active)
Test 1 - 2:
Test 3 - 6:
Test 7:
SYMPTOM
LOSS OF IGNITION RUN/START (ACTIVE)
WHEN MONITORED
Continuously with ignition ON.
SET CONDITION
With ignition ON, the ignition run/start circuit voltage is other than expected.
POSSIBLE CAUSES
- Ignition switch output run/start open
- Fuse #27 defective
- Fused IGN SW OPT run/start shorted to GND
- Fused ignition SW output run/start open
- ACM DEF, fused IGN run/start shorted
- Airbag control module defective, fused ignition run/start open