Either Squib Circuit Shorted/Battery (Active)
Test 1:
Test 2 - 3:
Test 4:
SYMPTOM
EITHER SQUIB CIRCUIT SHORT/BATTERY (ACTIVE)
WHEN MONITORED
Continuously with ignition ON.
SET CONDITION
With ignition ON, the driver or passenger airbag line 1 or line 2 circuit value is other than expected.
POSSIBLE CAUSES
- Passenger airbag line 1 or 2 short to voltage
- Clockspring defective, short to voltage
- Driver airbag line 1 or line 2 short to voltage
- ACM defective, DAB or PAB short to voltage