Either Squib Terminal Shorted/Ground (Active)
Test 1:
Test 2 - 3:
Test 4:
SYMPTOM
EITHER SQUIB TERMINAL SHORT/GROUND (ACTIVE)
WHEN MONITORED
Continuously with ignition ON.
SET CONDITION
With ignition ON, the driver or passenger airbag line 1 or line 2 circuit value is other than expected.
POSSIBLE CAUSES
- PAB line 1 or 2 short to ground
- Clockspring defective, short to ground
- DAB line 1 or 2 short to ground
- ACM DEF DAB or PAB short to ground