Either Squib Terminal Shorted to Battery (Active)
Test 1:
Tests 2 - 3:
Test 4:
SYMPTOM
EITHER SQUIB TERM SHORT TO BATTERY - ACTIVE
WHEN MONITORED
When the ignition is ON, the ACM monitors the voltage of the Driver Squib circuits.
SET CONDITION
The ACM has detected high voltage on the Driver Squib circuits.
POSSIBLE CAUSES
- Driver airbag module short to battery
- Clockspring DAB circuits short to battery
- Passenger airbag module circuits short to battery
- Either squib line 1 or line 2 short to battery
- ACM, either squib short to battery