Either Squib Terminal Shorted to Ground (Active)
Test 1:
Tests 2 - 3:
Test 4:
SYMPTOM
EITHER SQUIB TERM SHORT TO GROUND - ACTIVE
WHEN MONITORED
When the ignition is ON, the ACM monitors the voltage of the Driver Squib circuits.
SET CONDITION
The ACM has detected a short to ground in the Driver Squib circuits.
POSSIBLE CAUSES
- Driver airbag module short to ground
- Clockspring DAB circuits short to ground
- Passenger airbag circuit short to ground
- Either squib line 1 or line 2 short to ground
- ACM, Either squib term short to ground